Microtrol Co.

logo-microtrol

ClearWay

Perimeter Security System

ClearWay

CTS Series

Features and Functions

Specifications  

CTS350-X

Operating Range

500m

Operating Update Rate (Rotation Speed)

4 Hz

Operating Frequency

76 – 77 GHz

Range Resolution

0.175m

Azimuth Beamwidth

1.8°

Elevation Beamwidth

1.8°

Infill Elevation Beam

Standard

Measurement Rate

400 per rotation

Field of View

360°

Data Connection

1 Gbps Ethernet

Power Consumption

24 Watts

Power Supply

24 Volts DC or POE+*

Weight

6 Kg

Mounting Height

4 -5 metres

Safe Working Distance (from radome)

0cm

Operating Temperature 

-20°C to + 60°C

Environmental 

UL50/50E

IP 67
BS EN 60068-2-52:1996 Test Kb Severity 3

Compliance

CE, UKCA, ACMA Marked

EMC Directive

2014/30/EU

Low Voltage Directive

2014/35/EU

Radio Equipment Directive

2014/53/EU

Additional Notes

*PoE Power Supply Considerations

Recommended Operating Conditions

DC Supply Voltage: 36 to 57V

Absolute Maximum Ratings

DC Supply Voltage: -0.3 to 60V 

DC Supply Voltage Surge for 1ms: -0.6 to 80V

Exceeding these ratings may cause permanent damage to the product

KTS Series

Features and Functions

Specifications  

KTS350-X

Operating Frequency

Ka Band

Operating Range 

500m

Range Resolution

0.27m

Azimuth Beamwidth

1.8°

Elevation Beamwidth

3.6°

Infill Elevation Beam

Standard

Measurement Rate

400 per rotation

Field of View

360°

Data Connection

1 Gbps Ethernet

Power Consumption

30 Watts

60 Watts (with internal heater)

Power Supply

24 Volts DC 

Weight

11 Kg

Mounting Height

4 -5 metres

Safe Working Distance (from radome)

0.1m

Operating Temperature 

-20°C to + 60°C

Environmental 

UL50/50E

IP 67
BS EN 60068-2-52:1996 Test Kb Severity 3

Compliance

KC

FCC